Single ear endless clamp installation tutorial


The single-ear endless clamp, also known as the single-ear clamp, has no protrusion and gap in the inner ring, which can achieve uniform compression on the surface of the pipe fitting and provide 360° sealing protection. The following is the installation of the single ear endless clamp tutorial:

1. Preparation of tools and raw materials
Single-ear endless clamp: Select the appropriate size and ensure that the inner diameter of the clamp before clamping is slightly larger than the outer diameter of the hose.
Hose: Make sure the outer diameter of the hose matches the inner diameter of the clamp.
Clamp clamp: Select manual or pneumatic clamp clamp depending on the number of installations. Manual clamp clamp is suitable for a small number of assembly cases, pneumatic clamp clamp is suitable for mass production or assembly number of large cases.
Fittings (if required) : Ensure compatibility of fittings with hose and clamp.
Second, installation steps
Insert the clamp: Insert the single-ear endless clamp into the hose to ensure that the position of the clamp is correct, and the inner diameter of the clamp is slightly larger than the outer diameter of the hose, so that it can be clamped smoothly.
Adjust the air pressure (such as using pneumatic clamp clamp) : Increase the air pressure of the air compressor to the appropriate range (such as 6 to 8 kg), ensure that the air pressure is not high or low, to avoid the loss of the clamp clamp accessories or affect the clamping effect.
Select jaws: Select a clamp jaw set with the right jaws opening size. The opening size of the claw can not be too large, too large easy to press wrong; It should not be too small, otherwise it cannot be put into the ear of the clamp.
Clamp clamp: Align the clamp mouth with the root of the clamp ear and clamp the clamp in one step. Be careful not to apply pressure twice, and the two sides of the ear should not touch together after clamping. After clamping, you can judge whether the clamp is in place by observation and hand pushing.
Third, installation precautions
Choose the right clamp clamp: It is recommended to choose the clamp clamp that matches the quality of the clamp to ensure the clamping effect and the service life of the clamp clamp.
Avoid secondary pressure: When clamping the clamp, it should be in place at one time to avoid deformation or damage of the clamp caused by multiple pressures.
Check the tightness: After installation, check the tightness between the clamp and the hose to ensure that there is no leakage.
Pay attention to safe operation: When using pneumatic clamp clamp, pay attention to safe operation specifications to avoid accidents.
Through the above steps and precautions, you can correctly install the single-ear endless clamp, and ensure that it has good sealing and stability.

Related News